Datsons Electronics Pvt. Ltd.
Datsons Electronics Pvt. Ltd.
Pune, Maharashtra
SEND SMS
SEND EMAIL

Isolation Transformer Cubicle

Providing you the best range of isolation transformer cubicle power distribution unit and isolation transformer cubicle with effective & timely delivery.

Isolation Transformer Cubicle Power Distribution Unit

Isolation Transformer Cubicle Power Distribution Unit
  • Isolation Transformer Cubicle Power Distribution Unit
Ask For Price
Product Price :Get Latest Price

Product Details:

BrandDatsons
AltitudeLess Then 1000 Meter above sea level
Voltage415V 3W
Frequency50-60Hz
Capacity Range10-600 KVA
Relative HumidityUP TO 95% (Non Condensing)
ApplicationI/P OF UPS, O/P OF UPS, Bypass
Storage Temperature0-45 Degree C
Operating Temperature0 - 50 Degree C

Backed by a team of highly talented and experienced professionals, we are affianced in manufacturing and supplying an excellent quality Isolation Transformer Cubicle Power Distribution Unit. find Suitable for distributing continuous power supply, this isolation transformer it's the wide application in various commercial and domestic sectors. The offered isolation transformer is manufactured using well-tested components and ultra-modern technology in accordance with industry set standards. We ensure to provide this high-performance isolation transformer to our clients at most reasonable rates.

Standards:
As Per Applicable Clauses of is 2026-PART I & II-2010 & 2011, IS-11171, UL 1561/ ANSI 57.110 Oversizing Guidelines Only.

Features:

  • Short circuit - over temperature
  • Fan failure - protection
  • Embedded thermostat controlled forced cooling
  • Monitoring using digital true RMS multifunction meters
  • Covering parameters such as voltages, currents in all phases and Neutral, power factor
  • Branch circuit monitoring
  • Double sized neutral
  • Choice of top-bottom cable entry
Request
Callback
Yes! I am Interested
View PDF

Isolation Transformer Cubicle

Isolation Transformer Cubicle
  • Isolation Transformer Cubicle
Ask For Price
Product Price :Get Latest Price

Product Details:

ApplicationI/P OF UPS, O/P OF UPS, Bypass
Frequency50-60Hz
BrandDatsons
Operating Temperature0 - 50 Degree C
AltitudeLess Then 1000 Meter above sea level
Capacity Range10-600 KVA
Relative HumidityUP TO 95% (Non Condensing)
Storage Temperature0-45 Degree C
Voltage415V 3W

Our company is passionately involved in manufacturing and supplying a wide array of Isolation Transformer Cubicle that is available in assorted technical specifications as per the demands of the customers. It is perfectly designed & manufactured utilizing premium quality raw material and sound techniques under the strict supervision of skilled personnel. Our precious customers can avail the offered product at reasonable rates.

Standards:
As Per Applicable Clauses of is 2026-PART I & II-2010 & 2011, IS-11171, UL 1561/ ANSI 57.110 Oversizing Guidelines Only.

Features:
  • Galvanically shielded
  • K1-K7-K13-K20-rated
  • With soft start modules
  • Auto source selector modules
  • Phase seq. Correction modules
  • Unmatched functionality
  • High efficiency
  • Longer service life
Request
Callback
Yes! I am Interested
View PDF

ISOLATION TRANSFORMER CUBICLE

ISOLATION TRANSFORMER CUBICLE
  • ISOLATION TRANSFORMER CUBICLE
Ask For Price
Product Price :Get Latest Price
ISOLATION TRANSFORMER CUBICLE
CAPACITY RANGE Up to 2000kVA ( 2MVA)
Operating Voltage 415:415 ( Or As Per Required Voltage Ratio)
Main Incomer Isolator / MCCB /ACB/HRC FUSE
Input Phase Sequence Correction ( IPSC). Auto Phase Seuence Correction With MCCB / Cotactor.
Input Auto Source Selector (IASS). Auto Cahange Over Loagic With MCCB/ Contactor.
Voltage Monitoring VMR Relay
Metering DPM/Multifunction / Load Manager / LED/LCD/Intelegent highend Power Quality Analysers.
Transformer As Above Clause I Specs
K-Rating As Above Clause I Specs
Temperature Monitoring Temp meter
Main Outgoing Isolator / MCCB /ACB/HRC FUSE
Input-output Status/Indication ON/OFF/TRIP Solid State Indication , PFC As Requied.
Cooling Air Natural <60kVA < Forced Air Cooling
Cooling Mode Suction / Throw
Surge Arrestor SPD/TVSS Class C , Class B+C , Class B ( Type 1 , Type 2)
Maintenance Bypass Manual Change Over Switch Fpr Safe Bypass
Earth Fault/Leakage Detection Through EFR Relays
Soft Starters ( Inrush Current Limitor) Manual / Automatic
Panel Enclsoure CNC Machined BOX Type / Load Bearing Member Type / Compartmentalized Constructions
Ingress Protecion Up to IP 42
Fan Fail Indication Fan fail Indication and Hooter alarm i.e Audio-Visual
Over Temp Alarm OT Alarm as well as Indication i.e Audio-Visual.
Bus Bars Copper / Aluminum
Power Cables Panel Power harness

Note - Being Indoor application we recommend to go with lesser IP like IP-20 for better thermal performance

Request
Callback
Yes! I am Interested
X

Explore more products



Reach Us
Surya Sharma (Manager)
Gat No. 30, Sinhagad Road, Gorhe Budruk, Tal Haveli, Near Savali Resort
Pune- 411025, Maharashtra, India



Call Us

Share Us

F GT L


Send E-mailSend SMS